Mar 29, 2020 · root@busmap-api-test:~# clickhouse-client ClickHouse client version 20.3.5.21 (official build) Connecting to localhost:9000 as user default. Code: 209. DB::NetException: Timeout exceeded while reading from socket (127.0.0.1:9000) Can someone help me to figure out what is the problem and how I can solve it? Thanks,
Dec 21, 2020 · Hi, we have a cluster of 6 nodes and 3 shards. Node IP addresses are 10.255.0.141-10.255.0.146. Node hostnames are lvpclickhp01 - lvpclickhp06. In log files on first 4 nodes (shard1 and shard2) we ...
29.12.2021 · Digital Dream Labs wishes to thank Randall for his dedication to the Vector Technical Reference Manual, which is a fantastic resource. 800 - 999. If any of these Status Codes consistently appear, there could possibly be a hardware issue with Vector. Startup into Recovery Mode, Clear User Data, and use the Vector app to Reinstall Vector’s OS.
21.12.2020 · Hi, we have a cluster of 6 nodes and 3 shards. Node IP addresses are 10.255.0.141-10.255.0.146. Node hostnames are lvpclickhp01 - lvpclickhp06. In log files on first 4 nodes (shard1 and shard2) we have noticed many errors like this one: ...
09.08.2018 · It looks like the data for INSERT queries was not sent for more than 300 seconds. (Probably there was some data, then a pause for more than 300 seconds.) You should consult with author of the library: @kshvakov. Also you can increase timeouts: it is send_timeout and receive_timeout.
28.06.2020 · socket.timeout: timed out Traceback (most recent call last): ... clickhouse_driver.errors.SocketTimeoutError: Code: 209. None (None:None) The text was updated successfully, but these errors were encountered: Copy link Member xzkostyan commented Jul 7, 2020 #84. Sorry ...
Aug 09, 2018 · It looks like the data for INSERT queries was not sent for more than 300 seconds. (Probably there was some data, then a pause for more than 300 seconds.) You should consult with author of the library: @kshvakov. Also you can increase timeouts: it is send_timeout and receive_timeout.
Aug 19, 2021 · Return code/value Description; WSA_INVALID_HANDLE 6: Specified event object handle is invalid. An application attempts to use an event object, but the specified handle is not valid.
14.04.2021 · 👋🏾 I don't know if it's the same issue, but our internal Artifactory instance is also seeing npm ERR! code ERR_SOCKET_TIMEOUT errors sporadically on random modules after upgrading to npm@7.10.0. We had never had this issue with npm@6.
The settings are wrong and the client is trying to talk to the wrong machine, one that is not on the network. That could be an error in Hadoop configuration ...
19.08.2021 · Return code/value Description; WSA_INVALID_HANDLE 6: Specified event object handle is invalid. An application attempts to use an event object, but …
Apr 14, 2021 · to address the socket timeouts, you can try passing --fetch-timeout=600000 on the command line, which adjusts the connection timeout as well as the idle timeout. the default value is 5 minutes, which i would assume would be log enough, but clearly that's not the case.
28.03.2020 · root@busmap-api-test:~# clickhouse-client ClickHouse client version 20.3.5.21 (official build) Connecting to localhost:9000 as user default. Code: 209. DB::NetException: Timeout exceeded while reading from socket (127.0.0.1:9000) Can someone help me to figure out what is the problem and how I can solve it? Thanks,