Du lette etter:

veeam fc initiators list is empty

Veeam — Страница 2 — Мысли вслух
https://onix.me/tag/veeam/page/2
24.05.2019 · Ошибка «FC initiators list is empty» в Veeam Backup & Replication 9.5 Update 4 После обновления Veeam BR до обновления Update 4 стала появляться периодически ошибка «При бекапе виртуальной машины возникает ошибка « FC initiators list is empty «.
Google Alert - veeam - What's this Hyper-V
http://xkamolo2.blogspot.com › go...
Veeam fc initiators list is empty. dehnavi.me. Veeam Backup & Replication | Best Practices | 8. Direct Storage Access Using NetApp SnapDrive ...
Veeam Proxy not capable of doing Storage Snapshot
https://forums.veeam.com › veeam...
gglynn wrote: Also, Veeam uses its own built-in iSCSI initiator for scanning the NetApp for volumes and snapshots--which works great--so why has ...
3Par Storage Integration Not working - Veeam R&D Forums
https://forums.veeam.com/vmware-vsphere-f24/3par-storage-integration...
09.10.2021 · I have recently upgraded to v11 and since then the Storage integrated snapshots are not working jobs are failing with Error: FC initiators list is empty. When a job starts everything appears to be running as expected, in the Job you see Creating storage snapshots for backup and in vCenter the snapshot being taken. Then in the job.
3Par Storage Integration Not working - Veeam R&D Forums
https://forums.veeam.com › post42...
Error: FC initiators list is empty. I have checked all the sections of the configuration and just cannot figure out why this is happening.
Direct SAN Access - Veeam Software Help Center
helpcenter.veeam.com › docs › backup
Mar 04, 2021 · The Direct SAN access transport mode is recommended for VMs whose disks are located on shared VMFS SAN LUNs that are connected to ESXi hosts over FC, FCoE, iSCSI, and on shared SAS storage. In the Direct SAN access transport mode, Veeam Backup & Replication leverages VMware VADP to transport VM data directly from and to FC, FCoE and iSCSI ...
Configuring Backup from Storage Snapshots - User Guide for ...
https://helpcenter.veeam.com/docs/backup/vsphere/storage_backup.html
15.10.2021 · At the Storage step of the wizard, click Advanced, then click the Integration tab. Make sure that the Enable backup from storage snapshots check box is selected. By default, this option is enabled for all newly created jobs. If you add to the job multiple VMs whose disks are hosted on the same volume or LUN, select the Limit processed VM count ...
Configuring Backup Proxy for Storage Integration - User ...
https://helpcenter.veeam.com/docs/backup/vsphere/storage_configure...
01.10.2021 · Configuring Backup Proxy for Storage Integration. For some operations with storage snapshots, Veeam Backup & Replication requires a backup proxy. The backup proxy is used for two purposes: When Veeam Backup & Replication performs rescan and backup operations, it needs to read the content on storage volumes and snapshots.
3Par Storage Integration Not working - Veeam R&D Forums
forums.veeam.com › vmware-vsphere-f24 › 3par-storage
Oct 19, 2009 · I have recently upgraded to v11 and since then the Storage integrated snapshots are not working jobs are failing with Error: FC initiators list is empty. When a job starts everything appears to be running as expected, in the Job you see Creating storage snapshots for backup and in vCenter the snapshot being taken. Then in the job
Configuring Backup from Storage Snapshots - User Guide for ...
helpcenter.veeam.com › docs › backup
Oct 15, 2021 · At the Storage step of the wizard, click Advanced, then click the Integration tab. Make sure that the Enable backup from storage snapshots check box is selected. By default, this option is enabled for all newly created jobs. If you add to the job multiple VMs whose disks are hosted on the same volume or LUN, select the Limit processed VM count ...
Backups with storage based snapshots (Nimble) fails
https://forums.veeam.com › backu...
Failed to obtain list of VMs on LUN Temp-SS from snapshot Temp-SS of volume Temp Error: There is no initiators available. Any ideas ? b/r. Sven
FC initiators list is empty» в Veeam Backup & Replication 9.5 ...
https://onix.me › error-fc-initiators...
Ошибка «FC initiators list is empty» в Veeam Backup & Replication 9.5 Update 4. После обновления Veeam BR до обновления Update 4 стала ...
Using the iSCSI initiator within Veeam Backup ...
https://www.veeam.com/blog/using-the-iscsi-initiator-within-veeam...
12.04.2011 · Last week when I outlined a few considerations about whether to install Veeam Backup & Replication as a virtual or physical machine, a follow-up conversation reminded me of an important configuration scenario. If Veeam Backup & Replication is installed on a virtual machine with an iSCSI storage processor as the production storage for vSphere, you can …
Configuring Backup Proxy for Storage Integration
https://helpcenter.veeam.com › docs
For storage rescan, Veeam Backup & Replication uses its own initiator. For this reason, a Microsoft iSCSI Software initiator (Open-iSCSI) ...
Configuring Backup Proxy for Storage Integration - User Guide ...
helpcenter.veeam.com › docs › backup
Oct 01, 2021 · Instant First Class Disk (FCD) Recovery. Performing Instant FCD Recovery. Before You Begin; Step 1. Launch Instant Disk Recovery Wizard; Step 2. Select Source VM; Step 3. Select Restore Point; Step 4. Select Mount Mode; Step 5. Select Virtual Disks to Restore; Step 6. Specify Target Cluster; Step 7. Select Destination for FCD Updates; Step 8. Specify Restore Reason; Step 9.
Configuring Backup from Storage Snapshots - User Guide for ...
https://helpcenter.veeam.com › docs
You can instruct Veeam Backup & Replication to use Backup from Storage ... Note: A backup proxy that you select must be added to the list of ...
Using the iSCSI initiator within Veeam Backup & Replication ...
www.veeam.com › blog › using-the-iscsi-initiator
Apr 12, 2011 · Last week when I outlined a few considerations about whether to install Veeam Backup & Replication as a virtual or physical machine, a follow-up conversation reminded me of an important configuration scenario. If Veeam Backup & Replication is installed on a virtual machine with an iSCSI storage processor as the production storage for vSphere, you can configure the iSCSI initiator within the ...
KB1446: How to setup SAN access for use with Veeam Backup ...
www.veeam.com › kb1446
Dec 14, 2011 · Connect the storage using iSCSI or FC such that the volumes appear in Disk Management. This step may require adjusting setting for FC zoning and iSCSI whitelisting. It is advisable that prior to connecting the FC cable one ensure their HBA drivers are up to date. Once connected, VMFS LUNs should appear in Windows Disk Management snap-in.
KB1446: How to setup SAN access for use with Veeam ...
https://www.veeam.com › ...
In the Direct SAN access transport mode, Veeam Backup & Replication leverages VMware VADP to transport VM data directly from and to FC, ...
Rescanning Storage Systems - User Guide for VMware vSphere
https://helpcenter.veeam.com › docs
Otherwise, Veeam Backup & Replication will not be able to match storage volumes to VMware datastores and locate VMs on these storage volumes.
KB1446: How to setup SAN access for use with Veeam Backup ...
https://www.veeam.com/kb1446
14.12.2011 · The instructions below describe how to setup SAN access for use with Veeam Backup & Replication. Confirm the Windows Server to which the volumes will be presented is already added as a Proxy within Veeam Backup & Replication.; Connect the storage using iSCSI or FC such that the volumes appear in Disk Management.
Veeam 9.5 integration problems with Nimble FC array
https://forums.veeam.com › veeam...
When attempting to restore data from a Nimble storage snapshot the restore fails to mount snapshot with the error "collection was a fixed size".