Troubleshooting Guest Processing "Test Now ... - Veeam Software
www.veeam.com › kb3225
Jul 23, 2020 · In VMware environments, Veeam Backup & Replication can use two methods to connect to a guest: RPC or VIX. If RPC is testing successfully, it is generally acceptable for the VIX test to fail as it will not likely be used. However, if it is desired to have VIX succeed, please see the relevant section at the bottom of the solutions section.
Backup job reports Unfreeze Error (Over VIX) - Veeam Software
https://www.veeam.com/kb1787
08.07.2013 · Solution. Reinstall or perform a repair-install of VMware Tools. Reboot guest operating system of the backed-up VM if possible. In case neither of the above solutions work, see the VMware KB explaining how to troubleshoot VSS-related issues. In case none of the above helps, please contact MS Support for further assistance.
KB3225: Troubleshooting Guest Processing "Test Now" issues
https://www.veeam.com › ...
VIX is a network-less alternative method for Veeam Backup & Replication to connect to a guest. This functionality only exists when processing a ...
KB1788: Credentials Test or Job Fails when attempt to use VIX
https://www.veeam.com › ...
Veeam Backup & Replication uses the VIX API as a network-less connection method to perform Guest Processing when a VM cannot be contacted ...
Veeam Backup and VIX libraries: howto backup networkless VMs ...
www.virtualtothecore.com › veeam-backup-and-vix
Jun 25, 2013 · VIX connection is successful, and Veeam is able to install the temporary agent into the VM. How cool is that? If you also want to remove the initial error, and save some seconds in the job execution, since Veeam Backup & Replication v6.1 patch 1 (build 6.1.0.205) you can switch the VSS connection order, telling Veeam to try VIX connection first.
How to locate and collect VSS/VIX log files ... - Veeam Software
www.veeam.com › kb1789
Jul 08, 2013 · This article documents how to locate and gather the VSS and VIX log files for troubleshooting investigation. Cause While investigating an issue related to Application Aware Processing or Indexing additional logs must be gathered manually from the Guest OS for the VM that is failing to backup.
KB1788: Credentials Test or Job Fails when attempt to use VIX
https://www.veeam.com/kb1788
08.07.2013 · Veeam Backup & Replication uses the VIX API as a network-less connection method to perform Guest Processing when a VM cannot be contacted directly via RPC. Due to the way VIX operates, it is blocked by Windows User Account Controls. Also, because VIX relies on VMware Tools, if VMware Tools is out of date, issues may occur.
Guest Interaction Proxy - Veeam Software Help Center
https://helpcenter.veeam.com/docs/backup/vsphere/guest_interaction...
22.11.2021 · The role of a guest interaction proxy can be assigned to a Microsoft Windows server (physical or virtual). You must add the machine to the Veeam Backup & Replication console as a managed server. Guest interaction proxy must have either a LAN or VIX connection to the VM that will be processed. You do not have to set up both connections — only ...
Veeam Backup and VIX libraries - Virtual to the Core
https://www.virtualtothecore.com › ...
Basically, they allow for direct interaction between the guest operating system inside a VM using the hypervisor running it, without any need ...
How to fix Veeam VIX & RPC errors - Antonio Arienzo: the blog
https://arienzo.net › blog › how-to-...
I had this errors: -Error: Cannot upload file to admin share [C:\Windows]. Cannot create folder in guest: [C:\Windows\VeeamGuestHelpersTest].VIX Error: A ...
How to locate and collect VSS/VIX log ... - Veeam Software
https://www.veeam.com/kb1789
08.07.2013 · This KB will show you step by step how to locate the VSS/VIX log files that are not normally retrieved by the support wizard. 1-800-691-1991 | 9am ... Please note that no Veeam Backup and Replication task should be running against the …
KB3225: Troubleshooting Guest Processing ... - Veeam Software
https://www.veeam.com/kb3225
23.07.2020 · In VMware environments, Veeam Backup & Replication can use two methods to connect to a guest: RPC or VIX. If RPC is testing successfully, it is generally acceptable for the VIX test to fail as it will not likely be used. However, if it is desired to have VIX succeed, please see the relevant section at the bottom of the solutions section.
connecting to guest os via vix failed. - Veeam R&D Forums
https://forums.veeam.com › conne...
VIX - Veeam connects to the ESXi hosts and opens a network less connection to the VM by using the VIX communication channel of the VMware Tools.
VMware Backups - Veeam Backup & Replication Best Practice ...
https://bp.veeam.com/vbr/Support/S_Vmware/backup.html
If there is no network connectivity with a Linux-based VM, Veeam Backup & Replication v10 now supports VIX processing for Linux OS’s too and will failover to this method. One thing to keep in mind is that Pre-freeze and post-thaw scripts for Linux do not perform elevation to root (sudo) when networkless processing (VIX) is used.
KB1788: Credentials Test or Job Fails when attempt to use VIX
www.veeam.com › kb1788
Jul 08, 2013 · Veeam Backup & Replication uses the VIX API as a network-less connection method to perform Guest Processing when a VM cannot be contacted directly via RPC. Due to the way VIX operates, it is blocked by Windows User Account Controls. Also, because VIX relies on VMware Tools, if VMware Tools is out of date, issues may occur.
VIX vs RPC? - Veeam R&D Forums
https://forums.veeam.com › vix-vs...
Use PRC and configure the firewall to allow the RPC ports. 2. Use VIX. I'm thinking about using VIX and changing the Veeam backup servers and ...
Veeam Backup and VIX libraries: howto backup networkless ...
https://www.virtualtothecore.com/veeam-backup-and-vix-libraries-howto...
25.06.2013 · VIX connection is successful, and Veeam is able to install the temporary agent into the VM. How cool is that? If you also want to remove the initial error, and save some seconds in the job execution, since Veeam Backup & Replication v6.1 patch 1 (build 6.1.0.205) you can switch the VSS connection order, telling Veeam to try VIX connection first.
VIX with VMWare Tools newer than 10.1.15 - Veeam R&D Forums
forums.veeam.com › vmware-vsphere-f24 › vix-with
Oct 28, 2010 · It looks like with the newer VMWare tools when VIX logs it there is an event in the event viewer about loading a temporary profile for the VIX user then Veeam fails to install the guest agent. If I login to the console then run the backup while logged in then guest processing works.
Can you disable VIX functionality from Veeam side?
https://forums.veeam.com › can-yo...
Windows server 2016 Proxys, physical. VMware 6.7 U2+ Veeam 9.5 Update 4b. I have a weird issue regarding VIX. I want and is doing backups over ...
VMware Backups - Veeam Software
https://bp.veeam.com › vbr › backup
If there is no network connectivity to the VM guest OS, Veeam Backup & Replication uses the communication channel provided by VMware Tools (VIX) to interact ...
Guest Interaction Proxy - User Guide for VMware vSphere
https://helpcenter.veeam.com › docs
... Veeam Backup & Replication console as a managed server. Guest interaction proxy must have either a LAN or VIX connection to the VM that ...
connecting to guest os via vix failed. - Veeam R&D Forums
https://forums.veeam.com/vmware-vsphere-f24/connecting-to-guest-os-via...
28.01.2015 · You see, when Veeam performs a backup it will first try to connect with RPC. Only if RPC fails will it try with VIX. As you can see in your above log extract RPC succeeds. Hence you can ignore the VIX error, and there is no need to disable UAC in the guest or to back up as the actual "administrator" login.
Connecting to guest OS via VIX error … error 4 – Notes ...
https://notesfrommwhite.net/2016/06/28/connecting-to-guest-os-via-vix...
28.06.2016 · Hello all, An irritating issue today was solved - with some help from Veeam forums. I recently went through the Veeam Certified Engineer training and test (yes I passed!). As a result of that learning, I wanted to enabled guest file indexing and / or application aware processing. Here is what it looks like:…
Application Aware Processing with VIX as a Service Provider
https://forums.veeam.com › applic...
Our Veeam backup server is also in a separate network. There are many cases where we are not able to get the built-in domain\Administrator ...
connecting to guest os via vix failed. - Veeam R&D Forums
forums.veeam.com › vmware-vsphere-f24 › connecting
Jan 29, 2015 · VIX - Veeam connects to the ESXi hosts and opens a network less connection to the VM by using the VIX communication channel of the VMware Tools. RPC is faster than VIX. Veeam tries first to connect by RPC and fallback to VIX. So if you can connect by RPC there is no need to fix the VIX connection. To allow VIX to work you need several things: