Du lette etter:

how to use direct solver in ansys

14.7. Equation Solvers - BME-MM
https://www.mm.bme.hu › thy_tool8
The ANSYS program offers a large number of iterative solvers as alternatives to the direct solvers (sparse solver). These alternatives in many cases can result ...
Choosing a Solver for FEM: Direct or Iterative? | SimScale
www.simscale.com › how-to-choose-solvers-for-fem
Jun 14, 2021 · Fig. 01 Screenshot of FEM solver options available in SimScale. As shown in Fig. 01, we can see that, for structural mechanics simulations, there are several options available in the numerics section of the SimScale cloud-based platform. Of these, Multfront, MUMPS, and LDLT are direct solvers, while PETSc and GCPC are iterative solvers.
Usage and Performance Ansys equation solvers
https://www.tynecomp.co.uk › solver_2002
Sparse Solver Memory Usage Example 1 (cont.) ANSYS 6.0 memory allocation. Initial memory increased to 800 Mbytes. 800 Mbytes exceeds. Optimal I/ ...
Does non-linear analysis in ANSYS also make use of direct ...
https://forum.ansys.com/discussion/30407/does-non-linear-analysis-in...
05.08.2021 · As you note, the direct solver, also called the SPARSE SOLVER, uses LU decomposition to solve the stiffness matrix equation. The PCG solver uses an iterative algorithm to solve the stiffness matrix equation. In a linear analysis, that is done once. In a nonlinear analysis, that is done for every dot on the N-R Convergence plot (every nonlinear ...
Choosing a Solver for FEM: Direct or Iterative? | SimScale
https://www.simscale.com › 2016/08
In contrast to the direct solver, the iterative solver starts by assuming an approximate solution for the unknowns {u}. The solution is iterated ...
Solutions to Linear Systems of Equations: Direct and Iterative ...
https://www.comsol.com › blogs
The direct solvers will use more memory than the iterative solvers, but can be more robust. Iterative solvers approach the solution gradually, ...
Does non-linear analysis in ANSYS also make use of direct ...
https://forum.ansys.com/discussion/30407/does-non-linear-analysis-in...
Large models often solve in less time using the Iterative PCG solver or won't run at all with the Direct Sparse solver. The PCG solver uses less memory to run in Shared Memory than in Distributed Memory so the largest models may require unticking the Distributed box.
Does non-linear analysis in ANSYS also make use of direct ...
forum.ansys.com › discussion › 30407
Aug 06, 2021 · As you note, the direct solver, also called the SPARSE SOLVER, uses LU decomposition to solve the stiffness matrix equation. The PCG solver uses an iterative algorithm to solve the stiffness matrix equation. In a linear analysis, that is done once. In a nonlinear analysis, that is done for every dot on the N-R Convergence plot (every nonlinear ...
ANSYS Direct Solver vs Iterative Solver - Ansys Learning Forum
https://forum.ansys.com › discussion
However the stress become 400 MPa. Is there anything that i also need to change when i use direct solver? In addition under the geometry, i ...
ANSYS Solvers: Usage and Performance
tynecomp.co.uk › Xansys › solver_2002
ANSYS largest memory block available 588214172 : 560.96 Mbytes ANSYS memory in use 256482560 : 244.60 Mbytes Total Time (sec) for Sparse Assembly 63.53 cpu 69.02 wall Heap space available at start of BCSSL4: nHeap= 75619667 D.P. words 576.93 Mbytes Sparse Solver Memory Usage Example 1 2 Million DOF Sparse solver job
Computer suddenly restarts when using direct solver in ANSYS ...
www.researchgate.net › post › Computer_suddenly
Hi, I've being using ANSYS mechanical 18.2 (direct and iterative solver) in windows 7 without any issue. Recently I upgraded to a better performing (more cores and with more RAM) workstation which ...
ADVANCING ANALYSIS CAPABILITIES IN ANSYS ...
https://etna.math.kent.edu › pp106-121.dir
Solver changes that reduce memory usage may also increase disk usage and time to solution. Iterative solvers may provide a faster method to solve linear systems ...
Sparse Solver - an overview | ScienceDirect Topics
https://www.sciencedirect.com › sp...
) The sparse solver is a frontal type solver that has been optimized for sparsely populated matrices like those found in finite element analysis. From: ANSYS ...
In simple words, what is the difference between direct and ...
https://www.quora.com › In-simple...
A direct solver gives the exact solution to the system of equations that define the FE model. So for a system represented by , the exact solution is where ...
ANSYS Solvers: Usage and Performance
https://tynecomp.co.uk/Xansys/solver_2002.pdf
ANSYS largest memory block available 10268444 : 9.79 Mbytes ANSYS memory in use 1323917280 : 1262.59 Mbytes End of PcgEnd ANSYS largest memory block available 588214172 : 560.96 Mbytes ANSYS memory in use 256482560 : 244.60 Mbytes Total Time (sec) for Sparse Assembly 63.53 cpu 69.02 wall
Solution Information: Monitoring your Solves in ANSYS ...
www.padtinc.com › blog › solution-information
Jul 12, 2012 · Solver Output. When you click on the Solution Information branch in Solution, the graphics window turns to the worksheet window and you see Solver Output. This is the jobname.out file that ANSYS Mechanical APDL creates as it solves, and it is full of useful information.
Direct vs. iterative solvers in FEM - caendkölsch
https://caendkoelsch.wordpress.com › ...
Iterative solvers are suitable for computationally big problems as they can often be parallelized more efficiently using algorithms. But there ...
Choosing a Solver for FEM: Direct or Iterative? | SimScale
https://www.simscale.com/blog/2016/08/how-to-choose-solvers-for-fem
14.06.2021 · At each global iteration (of direct solver) or local + global iteration (of iterative solver), a simple algorithm is used to solve the equations. Here simple algorithms like Newton-Raphson, quasi-Newton, etc. are used. For the direct solvers, only the “Newton” option is available.
Solution Information: Monitoring your Solves in ANSYS ...
https://www.padtinc.com/blog/solution-information-monitoring-your...
12.07.2012 · Solver Output. When you click on the Solution Information branch in Solution, the graphics window turns to the worksheet window and you see Solver Output. This is the jobname.out file that ANSYS Mechanical APDL creates …